Flintec SB5 Stainless Steel, Single-Ended Beam Load Cell – Ricelake

0
71

Made for multiple-cell applications, such as floor scales and tank, bin and hopper weighing systems. Used exclusively in Rice lake Weighing Systems’ Paramounts® EP mounting systems. Millivolt/volt/ohm factory calibration assures matched outputs for easy calibration. Available in both NTEP Certified and Non-NTEP Certified ranges 5 nK TO 100 kN.

SB5 Load Cell Specifications

Full Scale Output:
2.0 mV/V
mV/V/ohm calibration

Output Resistance:
1,000 (± 2) ohm

Input Resistance:
1,100 (± 50) ohm

Material/Finish:
Stainless steel

Temperature:
Compensated range
14 °F to 104 °F (-10 °C to 40 °C)
Operating range
0 °F to 150 °F (-18 °C to 65 °C)

Seal Type:
Environmentally sealed, IP67

Safe Overload:
200% full scale

Safe Sideload:
100% full scale

Rated Excitation:
5 to 10 VDC (15 V maximum)

Combined Error:
± 0.03% full scale

Insulation Resistance:
10,000 megohm

Deflection at Capacity:
5 kN: 0.008 in
10 kN: 0.012 in
20 kN: 0.02 in
50 kN: 0.012 in

Cable Length:
5 to 20 kN: 10 ft
50 to 100 kN: 15 ft
Also available in 30 ft

Cable Diameter:
0.196 in
Polyurethane jacket

Cable Color Code:
Green +Excitation
Black –Excitation
White +Signal
Red –Signal
Yellow Shield

Warranty:
One-year limited

Approvals:
FM
NTEP
OIML

Source Link