Company News Latest News Load Cells Product News

Flintec UB1 Stainless Steel, S-Beam Load Cell – Ricelake

Designed for single or multiple-cell tension load applications, these stainless steel s-beams feature voltage factory calibration, assuring matched outputs for easy calibration in multiple-cell applications. Features hermetic sealing of the strain gauge area and cable entry, providing the ultimate in protection from outside elements. 20 ft of cable is included to simplify cable and load cell repairs. Capacities range from 10 kN to 50 kN.

UB1 Load Cell Specifications

Full Scale Output:
2.0 mV/V
mV/V/ohm calibrationOutput Resistance:
1,000 (± 2) ohm

Input Resistance:
1,100 (± 50) ohm

Material/Finish:
Stainless steel

Temperature:
Operating range
0 °F to 150 °F (-18 °C to 65 °C)

Seal Type:
Hermetically sealed, IP69K

Safe Overload:
200% full scaleRated Excitation:
5 to 10 VDC (15 V maximum)

Nonlinearity:
0 to -0.03% full scale

Hysteresis:
0 to +0.05% full scale

Combined Error:
± 0.03%

Insulation Resistance:
10,000 megohm

Cable Length:
20 ft

Cable Diameter:
0.196 in
Polyurethane jacketCable Color Code:
Green +Excitation
Black –Excitation
White +Signal
Red –Signal
Yellow Shield

Warranty:
One-year limited

Approvals:
FM
OIML

Source Link