RL75016SS-W Load Cell Specifications

Full Scale Output:
3.0 mV/V

Output Resistance:
700 (± 5) ohm

Input Resistance:
770 (± 10) ohm

Material/Finish:
Stainless steel

Temperature:
Operating range
0 °F to 150 °F (-18 °C to 65 °C)

Seal Type:
Welded-seal, IP67

Safe Overload:
100% full scale

Rated Excitation:
5 to 10 VDC (15 V max)

Hysteresis:
0.02% full scale

Linearity:
0.03% full scale

Cable Length:
25 ft

Cable Color Code:
Red +Excitation
Black  –Excitation
Green +Signal
White  –Signal

Warranty:
Two-year limited