top of page

VPG Sensortronics 65040A-1127W Alloy Steel, Double-Ended Beam Load Cell – Ricelake

This center-loaded, double-link load cell is made of alloy steel with an epoxy paint finish. It is a replacement for the RL75223 or RTI 5223 load cell, and is NTEP Certified. It comes with 40 ft of cable, and is available in 50,000 lb, 65,000 lb and 100,000 lb capacities.

65040A-1127W Load Cell Specifications

Full Scale Output: 3.0 mV/V

Output Resistance: 686 to 714 ohm

Input Resistance: 699 to 707 ohm

Material/Finish: High-alloy steel

Temperature: Compensated range 14 °F to 104 °F (-10 °C to 40 °C) Operating range 0 °F to 150 °F (-18 °C to 65 °C)

Seal Type: Welded-seal, IP67 (Conduit is recommended for maximum protection against the ingress of water and moisture through the cable entry)Safe Overload: 150% full scale

Safe Sideload: 100% full scale

Rated Excitation: 5 to 10 V DC (15 V maximum)

Non-repeatability: 0.01% full scale

Combined Error: 0.03% full scale

Insulation Resistance: 1,000 megohm

Deflection at Capacity: 50,000 lb: 0.018 in 65,000 lb: 0.022 in 100,000 lb: 0.034 inCable Length: 40 ft

Cable Diameter: 0.305 in polyurethane jacket

Cable Color Code: Red +Excitation Black –Excitation Green +Signal White –Signal

Warranty: One-year limited

Approvals: cFMus NTEP

3 views0 comments

Comentarios


bottom of page